NAME

SNMP::Info::Layer3::C6500 - SNMP Interface to Cisco Catalyst 6500 Layer 2/3 Switches running IOS and/or CatOS. Also Cisco Catalyst 2960, 2970, 3750 and 3850 series and blade switch CBS30x0 and CBS31x0 series running IOS.

AUTHOR

Max Baker

SYNOPSIS

# Let SNMP::Info determine the correct subclass for you.
my $c6500 = new SNMP::Info(
                       AutoSpecify => 1,
                       Debug       => 1,
                       # These arguments are passed directly to SNMP::Session
                       DestHost    => 'myswitch',
                       Community   => 'public',
                       Version     => 2
                       )
   or die "Can't connect to DestHost.\n";

my $class      = $c6500->class();
print "SNMP::Info determined this device to fall under subclass : $class\n";

DESCRIPTION

Abstraction subclass for Cisco Catalyst 6500 Layer 2/3 Switches.

These devices run IOS but have some of the same characteristics as the Catalyst WS-C family (5xxx). For example, forwarding tables are held in VLANs, and extended interface information is gleaned from CISCO-SWITCH-MIB.

It also supports the following IOS only series switches: Cisco Catalyst 2960, 2970, 3750 and 3850 series. Also blade switches from the CBS30x0 and CBS31x0 series.

Inherited Classes

SNMP::Info::CiscoStack
SNMP::Info::Layer3::CiscoSwitch
SNMP::Info::MAU

Required MIBs

CISCO-VIRTUAL-SWITCH-MIB
Inherited Classes' MIBs

See "Required MIBs" in SNMP::Info::CiscoStack for its own MIB requirements.

See "Required MIBs" in SNMP::Info::Layer3::CiscoSwitch for its own MIB requirements.

See "Required MIBs" in SNMP::Info::MAU for its own MIB requirements.

GLOBALS

These are methods that return scalar value from SNMP

$c6500->vendor()

Returns 'cisco'

$c6500->cvsSwitchMode()

Returns the Switch status: multiNode or standalone.

$c6500->is_virtual_switch()

Return 1 if the switch (cvsSwitchMode) is in multimode (VSS).

$c6500->serial()

Returns serial number of unit (falls back to entPhysicalSerialNum).

Globals imported from SNMP::Info::CiscoStack

See documentation in "GLOBALS" in SNMP::Info::CiscoStack for details.

Globals imported from SNMP::Info::Layer3::CiscoSwitch

See documentation in "GLOBALS" in SNMP::Info::Layer3::CiscoSwitch for details.

Globals imported from SNMP::Info::MAU

See documentation in "GLOBALS" in SNMP::Info::MAU for details.

TABLE METHODS

These are methods that return tables of information in the form of a reference to a hash.

Overrides

$c6500->i_duplex()

Returns reference to hash of iid to current link duplex setting.

Newer software versions return duplex based upon the result of $c6500->el_duplex(). Otherwise it uses the result of the call to CiscoStack::i_duplex().

See SNMP::Info::EtherLike for el_duplex() method and SNMP::Info::CiscoStack for its i_duplex() method.

$c6500->i_duplex_admin()

Returns reference to hash of iid to administrative duplex setting.

Newer software versions return duplex based upon the result of $c6500->p_duplex(). Otherwise it uses the result of the call to CiscoStack::i_duplex().

See SNMP::Info::CiscoStack for its i_duplex() and p_duplex() methods.

$c6500->set_i_duplex_admin(duplex, ifIndex)

Sets port duplex, must be supplied with duplex and port ifIndex.

Speed choices are 'auto', 'half', 'full'.

Crosses $c6500->p_port() with $c6500->p_duplex() to utilize port ifIndex.

Example:
my %if_map = reverse %{$c6500->interfaces()};
$c6500->set_i_duplex_admin('auto', $if_map{'FastEthernet0/1'})
    or die "Couldn't change port duplex. ",$c6500->error(1);
$c6500->set_i_speed_admin(speed, ifIndex)

Sets port speed, must be supplied with speed and port ifIndex.

Speed choices are '10', '100', '1000'.

Crosses $c6500->p_port() with $c6500->p_speed() to utilize port ifIndex.

Table Methods imported from SNMP::Info::CiscoStack

See documentation in "TABLE METHODS" in SNMP::Info::CiscoStack for details.

Table Methods imported from SNMP::Info::Layer3::CiscoSwitch

See documentation in "TABLE METHODS" in SNMP::Info::Layer3::CiscoSwitch for details.

Table Methods imported from SNMP::Info::MAU